home *** CD-ROM | disk | FTP | other *** search
-
- ⁄ƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒø
- ≥ This Program brought to you through the facilities of ≥
- ≥ *** SIMPLE SOFTWARE COMPANY *** ≥
- ≥ P.O BOX 8184 ≥
- ≥ NEW ORLEANS, LA. 70182 ≥
- ≥ >>>>>>>> Custom Programming <<<<<<<< ≥
- ≥ Voice (504) 288-6550 Data (504) 283-9785 ≥
- ≥ Database - Accounting - Telecommunications - DOS Utilities ≥
- ≥ Terry Tekippe, Ph.D, Gary M. Raymond, Programmers ≥
- ¿ƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒƒŸ
- by Gary M. Raymond
-
- Here is a summary of technical modem information collected from
- many sources over the past few years. Hopefully it will serve you
- as it has helped us. The information lacks great detail but has
- all the elemental information necessary for code writers.
-
- Standard IBM Default Values shown here.
-
- Vector Address = IRQ# plus 8
-
- PORT DEC HEX ISR VEC ADD IRQ OCW1 MASK
-
- COM1 1016 3F8 IRQ4 12d(0xC) AND 0xEF (or) AND (NOT 0x10)
- COM2 760 2F8 IRQ3 11d(0xB) AND 0xF7 (or) AND (NOT 0x8)
- COM3 1000 3E8 IRQ4 12d(0xC) AND 0xEF (or) AND (NOT 0x10)
- COM4 744 2E8 IRQ3 11d(0xB) AND 0xF7 (or) AND (NOT 0x8)
-
- IRQ1 AND 0xFD (various bit mask operations for OCW1 register
- IRQ2 AND 0xEF depending on Interrupt Request Line in use)
- IRQ3 AND 0xF7
- IRQ4 AND 0xEF
- IRQ5 AND 0xDF
- IRQ6 AND 0xBF
- IRQ7 AND 0x7F
-
- NOTE: AT PC's may address many
- additional serial port
- addresses not mentioned here.
-
-
- REGISTER (EXAMPLE: MCR for COM1 = 3F8+4 or 3FC)
- ---------------------------------------------
- IER = BASE + 1 ; Interrupt Enable Register
- IIR = BASE + 2 ; Interrupt Identification Register
- LCR = BASE + 3 ; Line Control Register
- MCR = BASE + 4 ; Modem Control Register
- LSR = BASE + 5 ; Line Status Register
- MSR = BASE + 6 ; Modem Status Register
-
- IER BIT MAPPING
- ---------------------------------------------
- BIT Activates Action
- 0 = Data Received Read RDR
- 1 = THR empty Output to THR
- 2 = Data error/break Read LSR
- 3 = MSR change Read MSR
- 4 = zero
- 5 = zero
- 6 = zero
- 7 = zero
-
- IIR BIT MAPPING
- ---------------------------------------------
- BIT
- 0 = more than 1 intr has occured
- 1-2 = 00 change in MSR 10 data received
- 01 THR empty 11 recv error/break
- 3 = zero
- 4 = zero
- 5 = zero
- 6 = zero
- 7 = zero
-
- LCR BIT MAPPING
- ---------------------------------------------
- BIT
- 0-1 = Data Length 00=5bits 10=7bits
- 01=6bits 11=8bits
- 2 = Stop Bits 0=1bit 1=2bits
- 3-5 = Parity 000=Ignore 101=mark
- 100=ODD 111=space
- 110=EVEN
- 6 = Break Condition 0=disabled 1=enabled
- 7 = Port Toggle 0=Use THR/RDR/IER 1=Use BRDL/BRDH
-
- LSR BIT MAPPING
- ---------------------------------------------
- BIT
- 0 = Set DTR line active
- 1 = Set RTS line active
- 2 = USER BIT #1
- 3 = USER BIT #2
- 4 = UART loopback
- 5 = zero
- 6 = zero
- 7 = zero
-
- LSR BIT MAPPING
- ---------------------------------------------
- BIT
- 0 = byte in RDR (received)
- 1 = overrun in RDR
- 2 = Parity error detected
- 3 = Framing error (out of sync, no stop bit received)
- 4 = Break Detect
- 5 = THR empty
- 6 = TSR empty (removes char from THR)
- 7 = Time Out
-
- MSR BIT MAPPING
- ---------------------------------------------
- BIT
- 0 = change in [C]lear [T]o [S]end CTS
- 1 = change in [D]ata [S]et [R]eady DSR
- 2 = change in ring indicator RI
- 3 = change in [D]ata [C]arrier [D]etect DCD
- 4 = Clear to send ..... [CTS] set high
- 5 = Data set ready .... [DSR] set high
- 6 = Ring Indicator .... [RI] set high
- 7 = Data Carrier detect [DCD] set high
- ===================================================================
-
- AT ATTENTION COMMAND
- A/ REPEAT COMMAND
- A ANSWER MODE COMMAND
- B/B0 SELECT CCITT V.22 IN 1200 BPS
- B1 SELECT BELL 212A
- Dn DIAL COMMAND (n = DIAL STRING, 0-9, *, #, !, W, R, AND,
- E DISABLE ECHO
- E1 ENABLE ECHO
- H ON HOOK (HANG UP)
- H1 OFF HOOK
- I/I0 IDENTIFY
- I1 DISPLAY 000
- I2 DISPLAY OK
- I3 DISPLAY MESSAGE PROGRAM ROM
- L/L0 LOW VOLUME
- L1 LOW VOLUME
- L2 MEDIUM VOLUME
- L3 MAXIMUM SPEAKER VOLUME
- M/M0 DISABLE SPEAKER
- M1 SPEAKER ON UNTIL CARRIER
- M2 SPEAKER ALWAYS ON
- M3 DISABLE SPEAKER WHEN DIALING OR CARRIER
- O GO ON LINE
- O1 RETRAIN (2400 BPS MODE ONLY)
- Q/Q0 ENABLE RESULT CODES
- Q1 DISABLE RESULT CODES
- Sn=X S REGISTER WRITE (n = VALID S REG, X = ALLOWED VALUE SEE
- &F COMMAND)
- Sn? READ SPECIFIED S REGISTER (n = ANY VALID S REGISTER)
- V0 SELECT DIGIT RESULT CODE
- V1 SELECT WORD RESULT CODE
- X0 BLIND DIAL, DISPLAY "CONNECT"
- X1 BLIND DIAL, DISPLAY "CONNECT 1200/2400"
- X2 DETECT DIAL TONE, DISPLAY "CONNECT 1200/2400"
- X3 DETECT BUSY TONE, DISPLAY "CONNECT 1200/2400"
- X4 DIAL AND BUSY TONE DETECT, DISPLAY "CONNECT 1200/2400"
- Y0 DISABLE LONG SPACE DISCONNECT
- Y1 ENABLE LONG SPACE DISCONNECT
- Z SOFTWARE RESET
- +++ ESCAPE CODE (GO TO COMMAND MODE IF ON LINE)
- &C0 DCD ALWAYS ON
- &C1 DCD FOLLOWS REMOTE CARRIER STATUS
- &D0 IGNORE DTR
- &D1 GO TO COMMAND WHEN DTR ON TO OFF
- &D2 HANGUP AND GO TO COMMAND WHEN DTR ON TO OFF
- &D3 POWER UP RESET WHEN DTR ON TO OFF
- &F FETCH FACTORY CONFIGURATION for S REGESTERS
- &G0 NO GUARD TONE
- &G1 550 HZ GUARD TONE
- &G2 1800 HZ GUARD TONE
- &J0 SELECT RJ-11/RJ-41S/RJ-45S
- &J1 SELECT RJ-12/RJ-13
- &M0 SELECT ASYNCHRONOUS MODE
- &P0 MAKE BREAK RATIO FOR US (40/60)
- &P1 MAKE BREAK RATIO FOR FOREIGN STANDARD (33/66)
- &R0 CTS TRACKS RTS
- &R1 CTS ON WHEN MODEM READY IN DATA MODE
- &S0 DSR ALWAYS ON
- &S1 DSR FOLLOWS RE232 SPECIFICATION
- &T0 STOP TEST
- &T1 LOCAL ALB TEST
- &T3 LOCAL DLB
- &T ENABLE DLB REQUEST
- &T5 DISABLE DLB REQUEST
- &T6 REMOTE DLB
- &T7 REMOTE DLB AND SELF TEST
- &T8 LOCAL ALB AND SELF TEST
- &V VIEW PROFILE
-
-
- S-REG ADDRESS DEFAULT VALID RANGE DESCRIPTION
-
- S0 228 0 0-255 RING TO ANSWER ON
- S1 229 0 0-255 RING COUNT
- S2 230 43 0-127 ESCAPE CODE CHARACTER
- S3 231 13 0-127 CR CHARACTER
- S4 232 10 0-127 LF CHARACTER
- S5 233 8 0-127 BS CHARACTER
- S6 234 2 0-255 WAIT FOR DIAL TONE
- S7 235 30 1-30 WAIT FOR DATA CARRIER
- S8 236 2 0-255 PAUSE TIME FOR COMMA
- S9 237 6 1-255(.1SEC) CARRIER DET RESP. TIME
- S10 238 14 1-255(.1SEC) LOST CARRIER TO HANG UP
- DELAY
- S11 239 TOUCH TONE DURATION
- S12 240 50 0-255 ESCAPE CODE GUARD TIME
- (1/50SEC)
- S13 241 NOT USED
- S14 242 AAH BIT MAPPED OPTION REG
- S15 243 NOT USED
- S16 244 0 MODEM TEST OPTIONS
- S17 245 NOT USED
- S18 246 0 0-255 TEST TIMER
- S19 247 NOT USED
- S20 248 NOT USED
- S21 249 0 BIT MAPPED OPTIONS REG
- S22 250 76 BIT MAPPED OPTIONS REG
- S23 251 7 BIT MAPPED OPTIONS REG
- S24 252 NOT USED
- S25 253 5 0-255(.01SEC) DELAY TO DTR (SYNC ONLY)
- S26 254 1 0-255(.01SEC) RTS TO CTS DELAY (HALF
- DUP)
- S27 255 40H BIT MAPPED OPTION REG
-
-
-
- RESULT CODES
- DIGIT WORD RESULT
-
- 0 OK Command executed without error.
- 1 CONNECT Carrier detected (300 bbs or 1200 bbs if
- X0 is set.)
- 2 RING Phone is ringing (will answer only if
- auto answer is enabled.)
- 3 NO CARRIER Carrier lost or never detected.
- 4 ERROR Error in command line, line too long, or
- invalid character format.
- 5 CONNECT 1200 Carrier detected at 1200 bbs if X1 set.
- 6 NO DIALTONE Displayed if no dialtone is detected
- within 5 seconds and X2 or X4 is set.
- 7 BUSY Displayed when a busy signal is
- detected and Z2 or X4 is set.
- 8 NO ANSWER Displayed when "@" dial modifier is used
- and phone continues to ring.
- 10 CONNECT 2400 Carrier detected at 2400 bbs. X1 or X2
- must be set.
-
-
- MODEM BELL 103 BELL 212 V.22 V.22 bis
- STANDARDS 300 1200 1200 2400
-
- BELL 300 300 300 300** 300**
-
- BELL 1200 1200* 1200 1200 1200
-
- CCITT 1200 1200* 1200 1200 1200
-
- CCITT 2400 2400* 1200 1200 2400
-
- CCITT 2400 300* 1200 1200 2400
-
-
- COMMAND DESCRIPTION
-
- AT COMMAND LINE PREFIX (ATTENTION CODE);
- PRECEDES COMMAND LINES EXCEPT +++ (ESCAPE)
- AND A/ (REPEAT) COMMANDS.
-
- A/ RE-EXECUTE LAST COMMAND LINE; (A/ IS NOT
- FOLLOWED BY A CARRIAGE RETURN).
-
- A OFF-HOOK IN ANSWER MODE.
- 5
-
- B SELECTS CCITT V.22 OPERATION WHEN
- COMMUNICATING AT 1200 BPS.
-
- B1 (Default) SELECTS BELL 212A OPERATION WHEN
- COMMUNICATING AT 1200 BPS.
-
- D DIAL NUMBER WHICH FOLLOWWD IN THE COMMAND
- LINE.
-
- E MODEM DOES NOT "ECHO" COMMANDS BACK TO
- TERMINAL.
-
-
- E1 (Default) MODEM SECHOS COMMANDS BACK TO TERMINAL.
-
- H (Default) ON-HOOK (HANG-UP) COMMAND.
-
- H1 GO OFF-HOOK.
-
- I REQUEST PRODUCT IDENTIFICATION CODE.
-
- I1 PERFORMS CHECKSUM ON FIRMWARE ROM; RETURNS
- CHECKSUM.
-
- I2 PERFORMS CHECKSUM ON FIRMWARE ROM; RETURNS
- OK OR ERROR.
-
- M SPEAKER OFF.
-
- M1 (Default) SPEAKER ON UNTIL CARRIER DETECTED.
-
- M2 SPEAKER ALWAYS ON.
-
- M3 SPEAKER ON UNTIL CARRIER DETECTED EXCEPT
- DURING DIALING.
-
- O RETURN TO ON-LINE STATE.
-
- O1 RETURN TO ON-LINE STATE AND INITIATE RETRAIN.
-
- Q (Default) MODEM RETURNS RESULT CODES.
-
- Q1 MODEM DOES NOT RETURN RESULT CODES.
-
- SRT=N SET REGISTER R TO VALUE N.
-
- SR? REQUEST CONTENTS OF REGISTER R.
-
-
- V SHORT FORM NUMERIC RESULT CODES.
-
- V1 (Default) FULL WORD RESULT CODES.
-
- X 300 BPS COMPATIBILITY MODE; CONNECT RESULT
- 6
- CODE ENABLED.
-
- X1 MODEM BLIND DIALS; ALL CONNECT XXXX RESULT
- CODES ENABLED; BUSY SIGNAL NOT DETECTED.
-
-
- X2 MODEM WAITS FOR DIAL TONE BEFORE DIALING;
- ALL CONNECT XXXX RESULT CODES ENABLED; MODEM
- SEND BUSY RESULT CODE IF BUSY DETECTED.
-
- X3 MODEM BLIND DIALS; ALL CONNECT XXXX RESULT
- CODES ENABLED; MODEM SENDS BUSY CODE IF BUSY
- DETECTED.
-
- X4 (Default) MODEM WAITS FOR DIAL TONE BEFORE DIALING;
- ALL CONNECT XXXX RESULT CODES ENABLED; BUSY
- SIGNAL DETECTED.
-
- Z LOAD STORED CONFIGURATION PROFILE.
-
- &C DCD ALWAYS ON.
-
- &C1 (Default) DCD ON INDICATES PRESENCE OF DATA CARRIER.
-
- &D (Default) MODEM IGNORES DTR.
-
- &D1 MODEM ASSUMES COMMAND STATE WHEN ON-TO-OFF
- TRANSITION DETECTED ON DTR.
-
- &D2 MODEM HANGS UP & ASSUMES COMMAND STATE.
- AUTO ANSWER NOT DISABLED UNLESS EXTERNALLY
- IMPLEMENTED BY (RI- # DTR-)= A6-.
-
- &D3 MODEM ASSUMES INITIALIZATION STATE UPON
- DETECTING AN ON-TO-OFF TRANSITION ON DTR.
-
- &F LOAD FACTORY CONFIGURATION PROFILE.
-
- &P (Default) PULSE DIAL MAKE/BREAK RATIO = 39/61 (UK/HK).
-
- &P1 PULSE DIAL MAKE/BREAK RATIO = 33/67 (UK/HK).
-
- &S DSR ALWAYS ON.
-
- &S1 DSR OPERATES IN ACCORDANCE WITH EIA RS-232-C
- SPEC.
-
- &T TERMINATE TEST PROGRESS.
-
- &T1 INITIATE LOCAL ANALOG LOOPBACK TEST.
-
- &T8 INITIATE LOCAL ANALOG LOOPBACK WITH SELF TEST.
-
- &Z STORE TELEPHONE NUMBER.
-
-
- EXPLANATIONS
-
- A Go off hook and answer phone immediately. The Model 2400
- immediately goes off hook, transmits the answer tone and
- waits for a carrier from the remote mode.
- Commands entered after the A command are ignored.
-
- A/ Repeat previous command. The last command executed by the
- Model 2400 will execute again. This command does not require
- the "AT" prefix or <cr> termination.
-
- Bn Bell/CCITT mode select.
-
- B0 - Selects CCITT V. 22 operation at 1200 bps.
- B1 - Selects BELL212A operation at 1200 bps (Default).
-
- Most 1200 bps modems in the United States operate using the
- BELL212A specification. In order to communicate with a modem
- conforming to the international CCITT V.22 standard, issue
- the B0 command before dialing.
-
- Dn Dial the number immediately following this command where
- n = digits 0 through 9 together with the dial modifiers
- listed below.
-
- Dial Modifiers: P Pulse dial
- T Tone dial
- R Originate call in answer mode
- W Wait for dial tone before dialing
- , Pause before dialing next digit
- ; Return to command mode after dialing
- @ Wait for quiet answer before dialing
- ! Flash-hook
- S Dial the number stores in RAM
-
- DIAL MODIFIERS
-
- P PULSE DIAL
-
- T TONE DIAL
-
- , PAUSE
-
- ! FLASH
-
- @ WAIT FOR SILENCE
-
- W WAIT FOR SECOND DIAL TONE
-
- ; RETURN TO COMMAND STATE AFTER DIALING
-
- R ORIGINATE CALL IN ANSWER MODE
-
- D DIAL STORED NUMBER
-
-
- ALL S REGISTER COMMANDS ARE ENTERED IN THE AT COMMAND LINE.
- EXAMPLE: AT S8=2 S2=43 S7=30
- TO READ THE VALUE IN ANY REGISTER USE
- AT S#? <CR>
- THE MODEM SHOULD ECHO THE VALUE FOUND IN THE REGISTER #
-
- REG Values Register function
- S0 0 AUTO ANSWER OFF
- 1-255 AUTO ANSWER ON, ANSWER ON INDICATED # OF RINGS
- S1 **0-255 RING COUNT (THIS IS A READ-ONLY REGISTER)
- S2 0-127 ESCAPE CHARACTER NORMALLY SET TO 43 OR "+"
- 127-255 ESCAPE FUNCTION DISABLED
- S3 0-127 END OF LINE CHARACTER NORMALLY SET TO 13 (CR)
- S4 0-127 LINE FEED CHARACTER NORMALLY SET TO 10 (LF)
- S5 0-127 BACKSPACE CHARACTER NORMALLY SET TO 8 (BS)
- S6 2-255 SEC PAUSE BEFORE DIALING (NORMALLY 2 SEC)
- S7 1-255 SEC WAIT FOR CARRIER (NORMALLY SET TO 30 SEC)
- S8 0-255 SEC PAUSE FOR COMMA IN DIAL STRING (NORMALLY SET TO 2 SEC)
- S9 1-255 .1SEC CARRIER VALIDATION TIME NORMALLY 6 (.6 SEC)
- S10 1-255 .1SEC LOSS OF CARRIER DISCONNECT DELAY NORMALLY 14 (1.4 SEC)
- S11 50-127 .1SEC TOUCH TONE DURATION. THE DEFAULT IS 90.
- S12 20-255 .02SE ESCAPE SEQENCE PAUSE NORMALLY 50 (1.0 SEC)
- S13 * POWER UP ASYNC DATA FORMAT (USE CHART BELOW)
- S14 * OPTION STATUS DEFULT AA (HEX CODE) (USE CHART BELOW)
- S16 * DEFULT 0. TEST STATUS (USE CHART BELOW)
- S18 0-255 SEC DEFULT 0. TEST TIMER (REMOTE TEST)
- S21 * DEFULT 0.OPTION STATUS (USE CHART BELOW)
- S22 * OPTION STATUS, DEFULT 76. (USE CHART BELOW)
- S23 * OPTION STATUS NORMALLY 07 (USE CHART BELOW)
- S25 0-255 SEC DTR DETECT DELAY NORMALLY 5 SEC
- ASYNC MODE, SYIC AUTO-DIAL AND SYIC MANUAL DIAL MODE .05 SEC
- S26 0-255 MS RTS TO CTS DELAY (1 MS)
- S27 * OPTION STATUS, DEFULT 40 (HEX CODE) (USE CHART BELOW)
-
- * REGISTERS USED BY MODEM PROCESSOR. DO NOT ALTER THESE
- * READ ONLY REGISTERS
-
- S13 DATA FORMAT:
-
- POSITION VALUE FUNCTION
- BIT 0 - NOT USED
- BIT 1 - NOT USED
- BIT 2 0 PARITY OFF
- 1 PARITY ON
- BIT 3 0 ODD PARITY
- 1 EVEN PARITY
- BIT 4 0 7 DATA BITS
- 1 8 DATA BITS
- BIT 5 0 BIT 8=0
- 1 BIT 8=1
- BIT 6 - NOT USED
- BIT 7 - NOT USED
-
- S14 DATA FORMAT:
- BIT 0 - NOT USED
- BIT 1 0 LOCAL CHARACTER ECHO OFF
- 1 LOCAL CHARACTER ECHO ON
- BIT 2 0 STATUS DISPLAYS ON
- 1 STATUS DISPLAYS OFF
- BIT 3 0 STATUS CODES SENT
- 1 STATUS MESSAGES SENT
- BIT 4 0 MODEM RESPONDS TO COMMANDS
- 1 MODEM IGNORES COMMANDS
- BIT 5 0 TONE-DIALING
- 1 PULSE-DIALING
- BIT 6 - NOT USED
- BIT 7 0 ANSWER MODE
- 1 ORIGINATE MODE
-
- S16 DATA FORMAT:
- BIT 0 0 ANALOG LOOP OFF
- 1 ANALOG LOOP ACTIVE
- BIT 1 - NOT USED
- BIT 2 0 DIGITAL LOOP OFF
- 1 DIGITAL LOOP ACTIVE
- BIT 3 0 REMOTE DIGITAL LOOP REQUESTED BY OTHER MODEM IS OFF
- 1 REMOTE DIGITAL LOOP REQUESTED BY OTHER MODEM IS ACTIVE
- BIT 4 0 REMOTE DIGITAL LOOP OFF
- 1 REMOTE DIGITAL LOOP ACTIVE
- BIT 5 0 SELF TEST RDL OFF
- 1 SELF TEST RDL ACTIVE
- BIT 6 0 SELF TEST ANALOG LOOP OFF
- 1 SELF TEST ANALOG LOOP ACTIVE
- BIT 7 - NOT USED
-
- S21 DATA FORMAT:
- BIT 0 0 RJ11/RJ41/45 JACK TYPE
- 1 RJ12/FJ13 JACK TYPE
- BIT 1 - NOT USED
- BIT 2 0 CTS FOLLOWS RTS
- 1 CTS FORCED ON
- BIT 3&4 0 MODEM IGNORES DTR
- 1 MODEM ASSUMES COMMAND STATE WHEN DTR TURNS OFF
- 2 MODEM ASSUMES COMMAND STATE AND DISABLES AUTO-ANSWER
- WHEN DTR TURNS OFF
- 3 MODEM RESETS WHEN DTR TURNS OFF
- BIT 5 0 DCD FORCED ON
- 1 DCD FOLLOWS CARRIER
- BIT 6 0 DSR FORCED ON
- 1 DSR BEHAVES NORMALLY
- BIT 7 0 LONG SPACE DISCONNECT DISABLED
- 1 LONG SPACE DISCONNECT ENABLED
-
- S22 DATA FORMAT:
- BIT 0&1 1 LOW SPEAKER VOLUME
- 2 MEDIUM SPEAKER VOLUME
- 3 HIGH SPEAKER VOLUME
- BIT 2&3 0 SPEAKER ALWAYS OFF
- 1 SPEAKER ON UNTIL CARRIER DETECTED
- 2 SPEAKER ALWAYS ON
- 3 SPEAKER OFF DURING DIALING THEN ON UNTIL CARRIER DETECTED
- BIT 4&5&6 0 X COMMAND IN EFFECT
- 4 X 1 COMMAND IN EFFECT
- 5 X 2 COMMAND IN EFFECT
- 6 X 3 COMMAND IN EFFECT
- 7 X 4 COMMAND IN EFFECT
- BIT 7 0 39/61 MAKE/BREAK RATIO (PULSE DIALING)
- 1 33/67 MAKE/BREAK RATIO
-
- S23 DATA FORMAT:
- BIT 0 0 REMOTE DIGITAL LOOP REQUEST DENIED
- 1 REMOTE DIGITAL LOOP REQUEST GRANTED
- BIT 1&2 0 0-300 BPS
- 1 600 BPS
- 2 1200 BPS
- 3 2400 BPS
- BIT 3 - NOT USED
- BIT 4&5 0 EVEN PARITY
- 1 PARITY BIT ALWAYS 0
- 2 ODD PARITY
- 3 PARITY BIT ALWAYS 1
- BIT 6&7 0 NO GUARD TONES
- 1 550 HZ GUARD TONE
- 2 1800 HZ GUARD TONE
-
- S27 DATA FORMAT:
- BIT 0&1 0 ASYNCRONOUS MODE
- 1 ASYNC/SYNC MODE
- 2 SYNC AUTO-DIAL
- 3 SYNC MANUAL DIAL
- BIT 2 0 PUBLIC PHONE LINE
- 1 LEASED LINE
- BIT 3 - NOT USED
- BIT 4&5 0 INTERNAL CLOCK USED
- 1 EXTERNAL CLOCK USED
- 2 SLAVED CLOCK USED
- BIT 6 0 CCITT V.22 PROTOCOL (1200 BPS)
- 1 BELL 212A (1200 BPS)
- BIT 7 - NOT USED
-
-
- OTHER MODEM COMMANDS:
-
- AT STANDARD LEAD IN SEQUENCE (ATTENTION)
- ATA FORCE ANSWER
- ATD DIAL (ATD ###-#####)
- P PULSE (ATDP ###-####)
- T TONE (ATDT ###-####)
- ATE1 ENABLE LOCAL CHARACTER ECHO
- ATE0 DISABLE LOCAL CHARACTER ECHO
- ATH1 FORCE LINE CONNECT
- ATH0 FORCE LINE DISCONNECT
- ATI ECHO VERSION TYPE
- ATL1 SPEAKER VOLUME LOW
- ATL2 SPEAKER VOLUME MEDIUM
- ATL3 SPEAKER VOLUME HIGH
- ATM0 SPEAKER ALWAYS OFF
- ATM1 SPEAKER ON EXCEPT WHILE CARRIER PRESENT
- ATM2 SPEAKER ALWAYS ON
- ATM3 SPEAKER ON EXCEPT WHILE DIALING AND CARRIER PRESENT
- ATO GO ONLINE AFTER ESCAPE OR WHILE IN COMMAND MODE
- ATQ0 STATUS DISPLAY ON
- ATQ1 STATUS DISPLAY OFF
- ATV0 STATUS MESSAGES SENT
- ATV1 STATUS CODES SENT
- ATX0 "CONNECT" (CODE 1) ALL SPEEDS NO DIAL TONE DETECTION
- ATX1 "CONNECT" (CODE 1) 0-300 BPS OR "CONNECT 1200" FOR 1200 OR
- "CONNECT 2400" FOR 2400 BPS NO DIAL TONE DETECTION
- ATX2 WAIT FOR DIAL TONE (CONNECT SPEEDS SHOWN AS FOR X1)
- ATX3 DETECT BUSY SIGNAL (CONNECT SPEEDS SHOWS AS FOR X1)
- ATX4 WAIT FOR DIAL TONE, DETECT BUSY SIGNAL (CONNECT SPEEDS SHOWS AS FOR X1)
-
- ATZ RESET TO POWER UP CONDITION (CLEARS ALL REGISTERS)
-
-
-
- 2400 MODEM SPECIAL COMMANDS: (* = FACTORY SETTING STANDARD)
-
- ATB0 CCITT V.22 AT 1200 BPS
- ATB1 BELL 212A AT 1200 BPS *
-
- AT &F RESTORE TO FACTORY C0NFIGURATION
- AT &G NO GUARD TONE *
- AT &G1 550 HZ GUARD TONE
- AT &G2 1800 HZ GUARD TONE
- AT &J RJ11/RJ41S/RJ45 JACK *
- AT &J2 RJ12/RJ13 JACK
- AT &L REGULAR PHONE LINE *
- AT &L1 LEASED LINE
- AT &M ASYNC OPERATION *
- AT &M1 ASYNC/SYNC OPERATION
- AT &M2 SYNC AUTO DIAL
- AT &M3 SYNC MANUAL DIAL
- AT &P 39/61 PULSE MAKE/BREAK RATIO *
- AT &P1 33/67 PULSE MAKE/BREAK RATIO
- AT &T4 GRANT RDL TEST REQUEST *
- AT &T5 DENY RDL TEST REQUEST
- AT &V VIEW STATUS OF ALL MODEM SETTINGS. SEE ALL S REGISTER SETTINGS AND
- INTERNAL MODEM COMMAND SETTINGS ON ONE SCREEN!
- AT &X SYNC CLOCK INTERNAL *
- AT &X1 SYNC CLOCK EXTERNAL
- AT &X2 SYNC CLOCK SLAVED
- AT &Z STORE DIAL COMMAND LINE
-
- DATA INTERFACE (2400)
- AT &C DCD ALWAYS ON
- AT &C1 DCD ON WHILE CARRIER PRESENT *
- AT &D DTR IGNORED *
- AT &D1 DTR FAIL DISCONNECT ENABLED (MODEM RETURNS TO COMMAND MODE)
- AT &D2 DTR FAIL DISCONNECT ENABLED (MODEM RETURNS TO COMMAND MODE, TURN
- AUTO ANSWER OFF)
- AT &D3 DTR FAIL DISCONNECT ENABLED (RESET MODEM)
-
-
- EOF()
-